Health
Simple blood test diagnoses Parkinson's disease long before symptoms appear — A new research report appearing in the December issue of the FASEB Journal (http://www.fasebj.org) shows how scientists from the United Kingdom have developed a simple blood test to…
Early sign of Alzheimer's reversed in lab — One of the earliest known impairments caused by Alzheimer's disease - loss of sense of smell - can be restored by removing a plaque-forming protein in a mouse model of the disease,…
Parental controls on embryonic development? — When a sperm fertilises an egg, each contributes a set of chromosomes to the resulting embryo, which at these very early stages is called a zygote. Early on, zygotic genes are inert,…
Newly discovered heart stem cells make muscle and bone — Researchers have identified a new and relatively abundant pool of stem cells in the heart. The findings in the December issue of Cell Stem Cell, a Cell Press publication, show that…
BUSM researchers develop blood test to detect membranous nephropathy — Research conducted by a pair of physicians at Boston University School of Medicine (BUSM) and Boston Medical Centre (BMC) has led to the development of a test that can help diagnose…
New hip implants no better than traditional implants — New hip implants appear to have no advantage over traditional implants, suggests a review of the evidence published on bmj.com today…
Action needed to improve men's health in Europe — Policies aimed specifically at men are urgently needed to improve the health of Europe's men, say experts on bmj.com today…
Probiotics reduce infections for patients in intensive care — Traumatic brain injury is associated with a profound suppression of the patient's ability to fight infection. At the same time the patient also often suffers hyper-inflammation, due…
High blood sugar levels in older women linked to colorectal cancer — Elevated blood sugar levels are associated with an increased risk of colorectal cancer, according to a study led by researchers at Albert Einstein College of Medicine of Yeshiva University.…
Engineered botulism toxins could have broader role in medicine — The most poisonous substance on Earth - already used medically in small doses to treat certain nerve disorders and facial wrinkles - could be re-engineered for an expanded role in helping…
Where am I? > Home > News > Health

Studies show everolimus-eluting stent implantation reduces restenosis and repeat revascularisation

Science Centric | 22 October 2010 18:25 GMT
Printable version A clip for your blog or website E-mail the story to a friend
Bookmark or share the story on your social network Vote for this article Decrease text size Increase text size
DON'T MISS —
Research may lead to improved hearing for some
Research may lead to improved hearing for some — Electric-acoustic stimulation research by an Arizona State University professor could help discover important acoustic cues…
Novel method of measuring insulin promises improvements in diabetes treatment
Novel method of measuring insulin promises improvements in diabetes treatment — A new method that uses nanotechnology to rapidly measure minute amounts of insulin is a major step toward developing the…
More Health

Two new studies have determined that everolimus-eluting stent (EES) implantation reduced the incidence of restenosis and repeat revascularisation in patients with calcified culprit lesions, and had fewer clinical events. Results show the rate of major cardiac adverse events in EES-treated patients with calcified lesions were higher than in those for noncalcified lesions, but remained lower than the results of previously reported stent studies. Details of both studies are published in the November issue of Catheterization and Cardiovascular Intervention, a peer-reviewed journal from The Society for Cardiovascular Angiography and Interventions.

The treatment of calcified coronary stenosis is associated with a high frequency of restenosis and target lesion revascularisation (TLR). Drug-eluting stents (DES), known to reduce the rates of restenosis and TLR in patients with relatively simple coronary artery lesions when compared with bare metal stents (BMS), are now successfully being used for more advanced lesions such as calcified coronary stenoses.

The XIENCE V EES emerged in 2008 as a new option in DES. Following favourable results with this device in the SPIRIT FIRST randomised study, the SPIRIT II and III trials were performed to evaluate the EES in comparison with the widely used TAXUS paclitaxel-eluting stent (PES) in the treatment of patients with coronary artery disease. The SPIRIT studies suggested positive outcomes for EES implantation in calcified culprit lesions, with the aim of the current analysis to confirm its safety and efficacy in patients with calcified and noncalcified culprit lesions.

In the first study, researchers from the Erasmus Medical Centre in the Netherlands identified 212 patients with 247 lesions, who were treated with EES alone. Target lesions were angiographically classified as none/mild, moderate, or severe grades of calcification. The population was divided into two groups: those with at least one target lesion moderately or severely calcified (the calcified group: 68 patients with 75 calcified lesions) and those with all target lesions having mild or no calcification (the noncalcified group: 144 patients). Six-month and 2-year angiographic follow-up and clinical follow-up to 3 years were completed.

At the 6-month and 2-year follow-ups, the calcified group (compared with the noncalcified group) had significantly higher rates of in-stent angiographic binary restenosis (ABR) and ischaemia-driven (ID) TLR, resulting in numerically higher major cardiac adverse events (MACE). While at 3 years, only ID-TLR tended to be higher in the calcified group than in the noncalcified group, resulting in numerically higher MACE.

'The geometry and rigidity of calcified culprit lesions often prevent optimal device delivery, deployment, and conformability,' explained study leader Patrick Serruys, M.D., Ph.D. 'Consequently, the treatment of this lesion subset with percutaneous coronary intervention (PCI) is associated with a high frequency of acute complications and a low-success rate. Our study showed high-clinical device success (98.7%), excellent clinical procedural success (100%), and the absence of MACE during the acute phase (up to 30 days after stent implantation) in the calcified group.'

Additionally, no patient in the calcified group suffered from stent thrombosis up to 3 years after PCI, while two thrombotic complications occurred in the noncalcified group. Although large population studies with long-term follow-up are mandatory, the authors concluded that EES implantation for calcified culprit lesions appears to be safe up to 3 years. This study also demonstrated that the rates of in-stent ABR (4.3%) and ID-TLR (5.9%) at 6 months for calcified culprit lesions are remarkably lower than that in previous BMS studies, in which these rates ranged from 12 to 23% and from 18 to 23%, respectively, suggesting that EES implantation is more effective for calcified culprit lesions than BMS implantation.

In a related study, researchers from the Wake Forrest University School of Medicine in North Carolina analysed data from SPIRIT III clinical trial to evaluate whether EES, with thinner stent struts and polymer, results in less adverse outcomes. Findings from the SPIRIT III trial indicated that the newer generation of DES, the EES, was associated with fewer clinical events than the first generation PES. In an effort to determine whether this benefit extended to all patient subgroups, Robert Applegate, MD, FSCAI, and colleagues assessed the impact of jailed side branches on clinical outcomes and periprocedural myonecrosis within each stent treatment group.

The Wake Forest researchers identified 113 patients in the EES group and 63 patients in the PES group who met the criteria of having a lesion with a jailed side branch (less than 2 mm diameter, and less than 50% stenosis). Two-year clinical outcomes were evaluated, revealing that MACE (cardiac death, myocardial infarctions (MI), or TLR) occurred in 6.8% of EES and 19.0% of PES jailed side branch patients, with numerically lower rates of MI and TLR in the EES group, with comparable rates of cardiac death.

Use of a PES was associated with an increase in rates of periprocedural creatine kinase-MB fraction (CK-MB) elevation, which was most prevalent in those patients with a jailed side branch. In contrast, rates of CK-MB elevation were similar in those patients receiving an EES, and lower when compared to PES, regardless of the presence or absence of a jailed side branch. The clinical outcomes at 1 and 2 years were similar in the EES treated patients with and without a jailed side branch, but were numerically higher in the PES treated patients with a jailed side branch compared to those without a jailed side branch.

Dr Applegate concluded, 'Our observations confirm previous studies demonstrating a relative increase in the incidence of periprocedural elevation of biomarkers with PES use, and demonstrate the absence of this phenomenon with EES.'

Source: Wiley-Blackwell


Leave a comment
The details you provide on this page [e-mail address] will not be used to send unsolicited e-mail, and will not be supplied to a third party! Please note that we can not promise to give everyone a response. Comments are fully moderated. Once approved they will be posted within 24 hours.
Expand the form to leave a comment

RSS FEEDS, NEWSLETTER
Find the topic you want. Science Centric offers several RSS feeds for the News section.

Or subscribe for our Newsletter, a free e-mail publication. It is published practically every day.

Gene variant increases risk of asthmaGene variant increases risk of asthma

— A tiny variation in a gene known as CHI3L1 increases susceptibility to asthma, bronchial hyperresponsiveness and decline in lung function, researchers report early…

Secrets of cellular signalling shed light on novel cancer stem cell therapiesSecrets of cellular signalling shed light on novel cancer stem cell therapies

— By revealing the inner workings of a common cell-to-cell signalling system, University of Michigan biologists have uncovered new clues about mysterious and contentious…

Needle-size device created to track tumours, radiation doseNeedle-size device created to track tumours, radiation dose

— Engineers at Purdue University are creating a wireless device designed to be injected into tumours to tell doctors the precise dose of radiation received and locate…

Long-term data show vertebroplasty for osteoporotic spinal fractures provides dramatic pain reliefLong-term data show vertebroplasty for osteoporotic spinal fractures provides dramatic pain relief

— The results of a five-year follow-up study of 884 osteoporosis patients bolster the use of vertebroplasty - an interventional radiology treatment for vertebral compression…

Popular tags in Health: cancer · diabetes · malaria · obesity